Opentrons logo
Cancel

Opentrons Flex Aliquoting Workstation

FLEX 2mL Aliquotting Workstation e1690211942144
Save 10%

Opentrons Flex Aliquoting Workstation

VERIFIED WORKSTATION APPLICATION
$20,000
$22,560

For scaling up and fully automating general liquid handling and tube-to-96-well-plate workflows

The Opentrons Flex Aliquoting Workstation includes the Flex Robot, Pipette, Tips, Labware, and Custom Protocol Development

With the Flex Aliquoting Workstation, you can automate your general liquid handling workflows at the scale you need to increase efficiency, reduce errors, and save hands-on time. Flex enables you to automate your tube-to-96-well-plate sample aliquoting workflows, as well as reagent aliquoting, serial dilutions, cherry picking, normalization, pooling and more.

The Flex Aliquoting Workstation can support the following workflow steps:

Tube Bubbles 1

Sample and Reagent Aliquoting

Well Plates

Serial Dilutions

Pipette

Cherry Picking

Robot 1

Normalization and Pooling

What’s in the box

Each Flex Aliquoting Workstation is configured with hardware, consumables, and custom protocol development for your general liquid handling and tube-to-plate workflows

AliquotRobots

Robot & Pipettes

  • Opentrons Flex Robot
  • Flex Gripper (Optional)
  • Flex 1-Channel Pipette (5-1000 µL)
  • Flex 1-Channel Pipette (1-50 µL) (Optional)
  • Custom Protocol Development
AliquotLabware

Accessories & Labware

  • Flex Waste Chute (Optional)
  • Flex Deck Expansion Set (Optional)
  • Flex Pipette Tips 1000 µL, Filtered (160 Racks/20 Refills)
  • NEST 12-Well Reservoirs (50 Count)
  • NEST 96-Well Plate, Flat (100 Count)
  • NEST 2.0 mL Microcentrifuge Tubes (500 Count)
  • 4-in-1 Tube Rack Set (4 Count)

Frequently Asked Questions

For FAQs about the OT-2 and Opentrons Flex, click here.

Yes, this can be achieved through the Opentrons app. You will need to be connected to a computer that is on the same WiFi or wired network as the liquid handler.

This is not an optical process. The robot uses capacitance sensors and a calibration probe (shipped with Flex pipettes) to perform automated calibration. Capacitive sensing for automated calibration is done by having a current run through the pipette’s metal tip at the bottom and then through a calibration tip until it’s grounded.

The Opentrons Flex 8-channel and 96-channel pipettes will aspirate and dispense the same volume with all channels at the same time. Volume is not independently controlled across channels.

OT-2 pipettes and OT-2 pipette tips are not compatible with the Opentrons Flex. The OT-2 pipette nose cone and Flex pipette nose cones are constructed differently, preventing cross-compatibility. OT-2 tip boxes/refills are also not compatible with the Flex.

Opentrons can only guarantee performance of the Flex when using our Flex pipette tips.

Flex Fits You

Find out more about the Opentrons Flex from an automation expert