Opentrons logo
Cancel
  ALL Pipettes

Opentrons Flex 1-Channel Pipette

Opentrons Flex 1-Channel pipettes enable highly accurate pipetting, optimized for automation.

Flex pipettes use air displacement technology to offer highly accurate pipetting with pipette volume ranges from 1 to 50 µL and 5 to 1000 μL. Smart sensors support automatic calibration, real-time positioning, and error detection. Choose the pipettes that fit your workflow — the gantry supports any two Flex 1-Channel or 8-Channel Pipettes — and swap them out yourself when your workflow changes.

Prices listed here are valid in the US and select other territories. Please get in touch with your local team for pricing for your territory.

FLEXONLY

999-00186
Volume Range

1-Year Warranty

Ships in 7 business days

Create a quote after you add to cart
Create a quote after you add to cart

Features

Accurate from 1 to 1000 µL

Flex pipettes use air displacement technology to offer highly accurate pipetting over high volume ranges

Modular pipetting heads

Install or swap out your pipettes yourself in minutes with minimal effort

Automated calibration

Smart sensors support automatic calibration, real-time positioning, and error detection

Tips built for automation

Automation-optimized tips designed specifically for the Flex

Tech Specs

Accuracy & Precision
Pipette Tip Size Volume Systematic Error Random Error
µL %D µL %CV
Flex 1-Channel Pipette (1–50 µL) 50µL
50µL
50µL
1
10
50
±8.00%
±1.50%
±1.25%
0.08µL
0.15µL
0.625µL
7.00%
0.50%
0.40%
Flex 1-Channel Pipette (5–1000 µL) 50µL
50µL
200µL
1,000µL
5
50
200
1000
±5.00%
±0.50%
±0.50%
±0.50%
0.25µL
0.25µL
1.00µL
5.00µL
2.50%
0.30%
0.15%
0.15%

Resources

Interactive Demos

FAQs

Yes, Flex pipettes include pressure sensors for detecting liquid height. These sensors are contained within the A1 and H12 channels on the 96-channel pipette, and the outermost channels on the 8-channel pipette (1 & 8).

The Opentrons Flex 8-channel and 96-channel pipettes will aspirate and dispense the same volume with all channels at the same time. Volume is not independently controlled across channels.

OT-2 pipettes and OT-2 pipette tips are not compatible with the Opentrons Flex. The OT-2 pipette nose cone and Flex pipette nose cones are constructed differently, preventing cross-compatibility. OT-2 tip boxes/refills are also not compatible with the Flex.

Opentrons can only guarantee performance of the Flex when using our Flex pipette tips.

Join a growing community

Thousands of labs in 40+ countries automate with Opentrons