Opentrons logo
  ALL Pipettes

Opentrons Flex 1-Channel Pipette

Opentrons Flex 1-Channel pipettes enable highly accurate pipetting, optimized for automation.

Flex pipettes use air displacement technology to offer highly accurate pipetting with pipette volume ranges from 1 to 50 µL and 5 to 1000 μL. Smart sensors support automatic calibration, real-time positioning, and error detection. Choose the pipettes that fit your workflow — the gantry supports any two Flex 1-Channel or 8-Channel Pipettes — and swap them out yourself when your workflow changes.

Prices listed here are valid in the US and select other territories. Please get in touch with your local team for pricing for your territory.

FLEXONLY

999-00186
Volume Range

1-Year Warranty

Ships in 7 business days

$3,250.00
Create a quote after you add to cart
Create a quote after you add to cart

Features

Accurate from 1 to 1000 µL

Flex pipettes use air displacement technology to offer highly accurate pipetting over high volume ranges

Modular pipetting heads

Install or swap out your pipettes yourself in minutes with minimal effort

Automated calibration

Smart sensors support automatic calibration, real-time positioning, and error detection

Tips built for automation

Automation-optimized tips designed specifically for the Flex

Tech Specs

Accuracy & Precision
Pipette Tip Size Volume Systematic Error Random Error
µL %D µL %CV
Flex 1-Channel Pipette (1–50 µL) 50µL
50µL
50µL
1
10
50
±8.00%
±1.50%
±1.25%
0.08µL
0.15µL
0.625µL
±7.00%
±0.50%
±0.40%
Flex 1-Channel Pipette (5–1000 µL) 50µL
50µL
200µL
1,000µL
5
50
200
1000
±5.00%
±0.50%
±0.50%
±0.50%
0.25µL
0.25µL
1.00µL
5.00µL
±2.50%
±0.30%
±0.15%
±0.15%

Resources

FAQs

Join a growing community

Thousands of labs in 40+ countries automate with Opentrons