Opentrons logo
Cancel
  ALL Workstations

Opentrons Flex SynBio Workstation

For scaling up and fully automating synthetic biology workflows.

With the Flex SynBio Workstation, you can automate a variety of synthetic biology workflows such as cloning and DNA assembly. The workstation is equipped with our Magnetic Block and Temperature Module to support any bead-based chemistry. You may choose to add the Thermocycler Module to your configuration for heated lid incubations and amplifications. Protocol development is included with the workstation to ensure the Flex is ready to run soon after installation.

Optional add-ons can be purchased at a 10% discount when ordered with the Flex Synbio Workstation*

Prices listed here are valid in the US and select other territories. Please get in touch with your local team for pricing for your territory.

991-00190

1-Year Warranty

Ships in 8 weeks

Create a quote after you add to cart
Create a quote after you add to cart

Features

Cloning

DNA assembly

Scale Up

Fully Automate

Tech Specs

Robots & Pipettes
  • Opentrons Flex Robot
  • Flex Gripper
  • Flex 1-Channel Pipette (5-1000 µl)
  • Flex 8-Channel Pipette (5-1000 µL)
  • Remote Protocol Development
Modules
  • Flex Magnetic Block
  • Temperature Module with Flex Caddy
Labware & Accessories
  • Flex Filter Tips, 20 Racks, 50 µL (1,920 tips)
  • Flex Filter Tips, 20 Racks, 1000 µL (1,920 tips)
  • Flex Filter Tips, 20 Refills, 50 µL (1,920 tips)
  • Flex Filter Tips, 20 Refills, 1000 µL (1,920 tips)
  • 4-in-1 Tube Rack Set
  • Tough 0.2 mL 96-Well PCR Plate, Full Skirt (25 Count)
  • NEST 2 mL 96-Well Deep Well Plate, V Bottom (50 Count)
  • NEST(R) 12-Well Reservoirs, 15 mL (50 Count)
  • NEST 1-Well Reservoirs, 290 mL (50 Count)
  • NEST 2.0 mL Microcentrifuge Tube (500 Count)
Optional Add-ons*
  • Opentrons Flex 1-Channel Pipette (1-50 μl)
  • Opentrons Flex 1-Channel Pipette (5-1000 μl)
  • Opentrons Flex 8-Channel Pipette (1-50 μl)
  • Opentrons Flex 8-Channel Pipette (5-1000 μl)
  • Opentrons Flex 96-Channel Pipette (5-1000 μl)
  • Opentrons Flex HEPA/UV Module
  • Thermocycler GEN2 with Opentrons Flex Caddy and Calibration Adapter
  • Heater-Shaker GEN1 with Opentrons Flex Caddy and Calibration Adapter
  • Opentrons Flex Waste Chute GEN1
  • Opentrons Flex Deck Expansion Set (4 count)
  • Heater-Shaker Deep Well Adapter
  • Heater-Shaker PCR Adapter

Resources

FAQs

You do not need to know how to code to use the Opentrons Flex platform. Protocols can be created using Opentrons’ plug-and-play protocol design tools. We also have an Applications Engineering team that can build custom protocols for you.

The Opentrons Flex requires on-site installation. We also offer both remote and on-site services solutions, as well as annual preventative maintenance.

You can find more information on Opentrons’ service offerings here.

Yes. Just like the OT-2, the Flex has full capability to accept custom or irregular labware. Our custom labware creation tools can be used to help create the compatible labware definitions that are required to use irregular labware with our software.

Users do not need a computer connected to the Opentrons Flex to run a protocol. Users will need to build the protocol on a computer and upload it to the Flex. Once uploaded, the protocol can be ran solely off the display.

No, Opentrons’ OT-2 pipettes will not be compatible with the Opentrons Flex. The Opentrons Flex is intended for use with our Flex Pipettes.

Yes, the Opentrons Flex’s side windows and front door are removable.

Crashes will be detected by the Opentrons Flex by comparing the actual vs. intended move of the embedded motors.

For example, If the robot expected 2 motor rotations, but only 1 rotation is completed due to a crash(which stops the motors from moving), then the robot would detect a discrepancy between intended move and actual. This would then throw an error and let you know you need to recalibrate.

You can use one computer running the Opentrons App to connect to multiple robots. This is true for both the Opentrons Flex and OT-2 robots.

Users can save up to 8 protocols to the Opentrons Flex display.

20 cm (8 in) of side and back clearance for cables, USB connections, and to dissipate exhaust from instruments like the Thermocycler or Temperature Module.

Join a growing community

Thousands of labs in 40+ countries automate with Opentrons