Opentrons logo
  ALL Modules

Heater-Shaker Module

The Opentrons Heater-Shaker Module, compatible with both the OT-2 and Flex robots, provides on-deck heating and orbital shaking of microplates. The module can be heated to 95C, and can shake samples from 200 to 3000 rpm. It is compatible with a number of deep-well and 96-well plates. The Heater-Shaker can be used simultaneously with other Opentrons modules.

The Heater-Shaker GEN1 is compatible with the new Opentrons Flex Robot when paired with the Flex Heater-Shaker Caddy and Calibration Adapter. The caddy sits below the deck to enable below-deck cable routing and labware placed on modules remain closer to the deck surface. The calibration adapter is used to calibrate the location of the module.

Prices listed here are valid in the US and select other territories. Please get in touch with your local team for pricing for your territory.

BOTH

999-00157
Configuration

1-Year Warranty

Ships in 7 business days

$5,250.00
Create a quote after you add to cart
Create a quote after you add to cart

Features

Orbital shaking range

200 to 3000 rpm range plus a shaking amplitude/pattern of 2 mm/orbital

Temperature range

Ambient to 95℃. Programmable temperature range from 37°C to 95°C in steps of 1°C and temperature accuracy ± 0.5°C at 55°C

Secure precious samples

Active clamping and automated locking on plate sides

Fixed home position

Allows robot to accurately access microplate wells

Compatibility

Compatible with ANSI/SLAS compliant consumables

One plate adapter included

Choose from a Universal Flat Adapter, 96 Flat Bottom Adapter, PCR Adapter, or a Deep Well Adapter.

Tech Specs

Dimensions

152 mm L x 90 mm W x 82 mm H

Orbital shaking range

200 to 3000 rpm

Shaking amplitude/pattern

2 mm/orbital

Programmable temperature range

From 37°C to 95°C in steps of 1°C

Temperature accuracy

± 0.5°C at 55°C

Weight

1.3 kg

Module power input

36V DC 6.1A DC

Power adapter input

100-240V, 50/60Hz

Adapters available

Resources

FAQs

Join a growing community

Thousands of labs in 40+ countries automate with Opentrons