Modules

All modules are optimized for automation and slot perfectly onto the deck of the OT-2.

Thermocycler Module

The Thermocycler Module is a fully automated on deck thermocycler with programmable lid and block temperatures. It has performance comparable to machines 5x its price, and enables automation of upstream and downstream workflow steps.

  • Pipette samples on OT-2 deck
  • Disposable seal system for preventing sample loss
  • Program lid temperatures up to 110℃
  • Program block temperatures from 4 - 99℃
  • Max working volume range: 10 - 100 µL
  • Recommended volume range for up to 80-sample PCR: 25 - 100 µL
Download the Thermocycler Module Manual
read whitepaper

Dimensions (w/o bracket)

316mm x 172mm x 312mm

Power adapter input

120-240VAC, 50/60Hz, 8.5-5A

Power

36V, 17.5A (630W max)

Mass

7.6 kg

Thermocycler Module

$4,000

buy now

Thermocycler Module

$4,000

buy now

Temperature Module (GEN2)

The Temperature Module sits securely on the deck of the OT-2 and holds plated reagents at temperatures between 4°C and 95°C.

  • Includes aluminum block to hold labware including 1.5mL tubes, 2mL tubes, and PCR strips
  • Standard size capable of holding 96-well plates and other labware on-deck
  • NOTE: it is highly recommended that users place water between aluminum thermal blocks and plastic well tubes, strips and/or plates​
read whitepaper

Dimensions (w/block)

1194 x 90 x 126mm (l/w/h)

Power adapter input

100-240VAC, 50/60Hz

Power

36V, 6.1A (220W max)

Mass

1.5kg

Temperature Module (GEN2) with Block

$2,500

buy now

Temperature Module (GEN2) with Block

$2,500

buy now

Magnetic Module (GEN2)

The Magnetic Module is a magnetic bead-based chemistry block for extraction and purification. It automatically engages and disengages high strength magnetic bars to seated well plates for magnetic bead-based purification protocols.

  • High-strength N42 neodymium magnets
  • Two adjustable plate brackets
  • Compatible with standard and deep well labware from 22 mm to 44 mm, various magnetic bead products, and protocols with volumes from 10 µL to 2 mL
read whitepaper

Dimensions (open)

316 x 172 x 312mm (l/w/h)

Dimensions (closed)

316 x 172 x 154mm (l/w/h)

Uniformity + Accuracy

± 0.5°C up to 95°C

Ramp Rate (block)

4°C/sec (MAX); 2.5°C/sec (AVG)

Power adapter input

100-240VAC, 50/60Hz

Power

36V, 6.1A (220W max)

Mass

1.5kg

Magnetic Module (GEN2)

$2,500

buy now

Magnetic Module (GEN2)

$2,500

buy now

Ready for Opentrons in your lab?