Highly accurate pipetting from 1 to 96 channels and optimized for automation
Flex pipettes use air displacement technology to offer highly accurate pipetting over high volume ranges
Install or swap out your pipettes yourself in minutes with minimal effort
Smart sensors support automatic calibration, real-time positioning, and error detection
Automation-optimized tips designed specifically for the Flex
Pipette | Tip Size | Volume | Systematic Error | Random Error | |
---|---|---|---|---|---|
µL | %D | µL | %CV | ||
Flex 1-Channel Pipette (1–50 µL) | 50µL 50µL 50µL |
1 10 50 |
±8.00% ±1.50% ±1.25% |
0.08µL 0.15µL 0.625µL |
±7.00% ±0.50% ±0.40% |
Flex 1-Channel Pipette (5–1000 µL) | 50µL 50µL 200µL 1,000µL |
5 50 200 1000 |
±5.00% ±0.50% ±0.50% ±0.50% |
0.25µL 0.25µL 1.00µL 5.00µL |
±2.50% ±0.30% ±0.15% ±0.15% |
Pipette | Tip Size | Volume | Systematic Error | Random Error | |
---|---|---|---|---|---|
µL | %D | µL | %CV | ||
Flex 8-Channel Pipette (1–50 µL) | 50µL 50µL 50µL |
1 10 50 |
±10.00% ±2.50% ±1.25% |
0.10µL 0.25µL 0.625µL |
±8.00% ±1.00% ±0.60% |
Flex 8-Channel Pipette (5–1000 µL) | 50µL 50µL 200µL 1,000µL |
5 50 200 1000 |
±8,00% ±2.50% ±1.00% ±0.70% |
0.40µL 1.25µL 2.00µL 7.00µL |
±4.00% ±0.60% ±0.25% ±0.15% |
Tip Size | Volume | %D | %CV |
---|---|---|---|
50μl | 5μl | ±10% | ±5% |
50μl | 50μl | ±2.5% | ±1.25% |
200μl | 200μl | ±1.5% | ±1.25% |
1,000μl | 1,000μl | ±1.5% | ±1.5% |
For FAQs about the Opentrons Flex, OT-2 and other products, click here.
Yes, Flex pipettes include pressure sensors for detecting liquid height. These sensors are contained within the A1 and H12 channels on the 96-channel pipette, and the outermost channels on the 8-channel pipette (1 & 8).
Yes, this process is now guided by the on deck touchscreen display. Through these improvements, it is easier to load/unload the pipettes with better alignment.
The Opentrons Flex 8-channel and 96-channel pipettes will aspirate and dispense the same volume with all channels at the same time. Volume is not independently controlled across channels.
OT-2 pipettes and OT-2 pipette tips are not compatible with the Opentrons Flex. The OT-2 pipette nose cone and Flex pipette nose cones are constructed differently, preventing cross-compatibility. OT-2 tip boxes/refills are also not compatible with the Flex.
Opentrons can only guarantee performance of the Flex when using our Flex pipette tips.