Performs nearly end-to-end next generation sequencing (NGS) for a range of genomic and drug discovery applications
Workstation includes the OT-2 robot, modules, and consumables needed to run NGS assays
The Opentrons NGS Workstation is an open-source liquid handling system that automates sample and library prep, reagent distribution, bead processing, and general biochemical and genomic transfers in your NGS and PCR applications.
This workstation automates protocols and workflows using any leading reagent or magnetic bead-based system in the market with accuracy and precision at the fraction of the cost.
This workstation can be used for the following applications:
Each Opentrons NGS Workstation is custom configured with the hardware, consumables, and protocols unique to your NGS assay. You’ll also enjoy free access to the Opentrons Protocol Designer, Python API, and Protocol Library.
This application has been fully tested and scientifically verified by Opentrons.
Next-generation sequencing (NGS) workflow includes preparing DNA libraries using commercially available and cost-effective DNA preparation kits as well as normalization and pooling data on the OT-2. We present data optimizing this workflow by using the OT-2 NGS workstation and an automated OT-2 protocol helps to improve the efficiency for DNA library preparation, normalization and pooling.
Demonstrated Method for DNA preparation on the OT-2 NGS Workstation
Figure 1. NGS with OT-2. The dotted line box indicate the NGS steps that can be automated on the OT-2
Application and workflow
Deck layout
Figure 2. Opentrons OT-2 deck layout equipped with modules, labware, and reagents.
Methodology
The experiment was repeated for 24 replicates of Lambda, and for 8 replicates of Human Genomic DNA from Promega.
The experiment was repeated for 24 replicates of fragmented Lambda, and for 8 replicates of fragmented Human Genomic DNA from Promega. Fragmentation was performed with NEB Fragmentase for 16 min for Lambda and 20 minutes for Human Genomic DNA and then cleaned up with AMPure XP Beads.
Data Presentation
Table 1. Comparison of NGS Sample Library Preps on the OT-2.
Figure 3. Uniform sample barcode representation. These pie charts demonstrate the even sample barcode balance within the sequencing run by overall read percentage.
Featured NGS protocols:
Still didn’t find what you’re looking for? Get a custom protocol developed for your assay.
Opentrons aims to provide the best customer experience with our system. We provide:
Custom Protocol Type | 1 Workflow | 3 Workflows | Turnaround Time |
---|---|---|---|
Standard Workflow Development | $1,000 | $2,750 | 2 weeks |
Expedited Workflow Development | $1,300 | $3,350 | 1 week |
If Opentrons hardware does not work for your assay needs, we offer a risk-free return on eligible hardware purchases. We provide a full refund in the amount found on your purchase order, credit card or pro-forma invoice including all associated shipping cost within a 60-day period.
Opentrons products (OT-2, modules, and pipettes) also comes with a free 1-year warranty and an option to buy another 1 year extended warranty.
Q: Can the Opentrons NGS workstation work on any kit?
A: Yes. It is an open-source platform that is kit agnostic and customizable for different assay needs.
Q: Can the Opentrons NGS workstation handle various NGS fluid types?
A: The OT-2 can work with various NGS fluid types with accuracy and precision. See our accuracy and precision tables. We have also published application notes such as Viscous Liquid Handling on the OT-2 and Volatile Liquid Handling on the OT-2 for our customers.
Q: What kind of labware can I use with the Opentrons platform?
A: Out of the box, the OT-2 can support any standard, automation-compatible / SBS footprint well plates, plus a wide range of snap-cap and screw-cap tubes up to a 50mL conical with our 4-in-1 Tube Rack. You can see the full range of supported labware in our Labware Library.
Q: Do you support custom labware?
A: The OT-2 can work with almost any piece of labware you’re using today, even if it’s custom-made.
If you need to use custom labware that has the same footprint as a common microplate, you can create a custom labware definition of your own in minutes using our Labware Creator.
If you need to use custom labware that doesn’t have the same footprint as a common microplate, our Applications Engineers can create one for you. Or, if you have some coding knowledge, you can create one yourself and 3D print a bracket or adapter to use it on the deck.
Q: Do I need to know how to code to use the Opentrons platform?
A: You do not need to know how to code to use the Opentrons platform. Protocols can be created using Opentrons’ plug-and-play protocol design tools. We also have an Applications Engineering team to help customers build protocols.
Q: Can I see a sample protocol?
A: All of our protocols are open-source and free to access on GitHub.
Q: Can I handle small volume transfers with the OT-2?
A: You can accurately and precisely handle volumes from 1-20µL with either our Opentrons 8-Channel P20 GEN2 Electronic Pipette or Opentrons Single-Channel P20 GEN2 Electronic Pipette. Pipettes are calibrated and factory tested at the 1µL setpoint, and come with a calibration certificate. However, even with testing and certification, handling low volume transfers via automated air displacement pipetting requires testing and optimization to ensure they meet your specifications