Opentrons Flex High Throughput NGS Workstation


Opentrons Flex robot bundle to support end-to-end NGS workflows in high throughput. Configured with a 96-channel pipette and modules to support 96 sample tagmentation, ligation, barcoding, a-tailing, amplification, bead purification, size selection etc. Add any pipette, module, or labware to your purchase of a workstation for a 10% discount.


All Opentrons Flex robots manufactured before Q3 2025 will require a robot upgrade to support the Opentrons Flex Stacker. The robot upgrade must be conducted by an on-site field service engineer. The cost of this upgrade and on-site visit are included.


Only 1 Opentrons Flex Stacker kit is required for each robot

Prices listed here are valid in the US and select other territories. Please get in touch with your local team for pricing for your territory.

991-00409-0
Pipette Volume Range

1-Year Warranty

Now accepting pre-orders

Create a quote after you add to cart
Create a quote after you add to cart

Features

Library Construction

Bead Clean Ups

Normalization and Pooling

Tech Specs

Robot & Pipettes
  • Opentrons Flex Robot
  • Flex Gripper
  • 1 Flex 96-Channel Pipette (5-1000 µL)
  • or 1 Flex 96-Channel Pipette (1-200µL)
Labware & Accessories
  • Flex Waste Chute GEN2
  • 2x Opentrons Flex 96-Channel Tip Rack Adapter (2 count)
  • Opentrons Flex Deck Expansion Set (4 count)
  • Opentrons Flex Filter Tips, 50 µL (20 Racks/20 Refills)
  • Opentrons Flex Filter Tips, 200 µL (20 Racks/20 Refills)
  • Opentrons Tough 0.2 mL 96-Well PCR Plate, Full Skirt (25 Count)
  • Opentrons Tough Auto-Sealing PCR Lids (20 count)
  • Opentrons Flex Deck Riser
  • NEST 12-Well Reservoirs, 15 mL (50 Count)
  • NEST 1-Well Reservoirs, 290 mL (50 Count)
  • NEST 2 mL 96-Well Deep Well Plate, V Bottom (50 Count)
  • NEST 2.0 mL Microcentrifuge Tube (500 Count)
  • 4-in-1 Tube Rack Set
  • Opentrons Flex Stacker Customer Kit
Modules
  • Flex Magnetic Block
  • Temperature Module
  • Thermocycler Module
  • 2x Opentrons Flex Stacker

Resources

FAQs

You do not need to know how to code to use the Opentrons Flex platform. Protocols can be created using Opentrons’ plug-and-play protocol design tools. We also have an Applications Engineering team that can build custom protocols for you.

The Opentrons Flex requires on-site installation. We also offer both remote and on-site services solutions, as well as annual preventative maintenance.

You can find more information on Opentrons’ service offerings here.

Yes. Just like the OT-2, the Flex has full capability to accept custom or irregular labware. Our custom labware creation tools can be used to help create the compatible labware definitions that are required to use irregular labware with our software.

Users do not need a computer connected to the Opentrons Flex to run a protocol. Users will need to build the protocol on a computer and upload it to the Flex. Once uploaded, the protocol can be ran solely off the display.

No, Opentrons’ OT-2 pipettes will not be compatible with the Opentrons Flex. The Opentrons Flex is intended for use with our Flex Pipettes.

Yes, the Opentrons Flex’s side windows and front door are removable.

Crashes will be detected by the Opentrons Flex by comparing the actual vs. intended move of the embedded motors.

For example, If the robot expected 2 motor rotations, but only 1 rotation is completed due to a crash(which stops the motors from moving), then the robot would detect a discrepancy between intended move and actual. This would then throw an error and let you know you need to recalibrate.

You can use one computer running the Opentrons App to connect to multiple robots. This is true for both the Opentrons Flex and OT-2 robots.

Users can save up to 8 protocols to the Opentrons Flex display.

20 cm (8 in) of side and back clearance for cables, USB connections, and to dissipate exhaust from instruments like the Thermocycler or Temperature Module.